INDICATEURS DE TABLEAU

Afficheur multimesure

INDICATEURS DE TABLEAU

Afficheur multimesure

Le Multimètre ECRAS  a la capacité de mesurer la tension de phase et de ligne, le courant de phase, la fréquence du réseau, le facteur de puissance, la puissance active, réactive et apparente.

Le Multimètre ECRAS se décline en 2 références ECRAS120 (sans port de communication) et ECRAS220 (avec port de communication RS485)

Nous répondons à tous vos besoins en Automatisme

General Seven Segment Display
Password Protection
Current Transformer Ratio 1 – 5000
Voltage Transformer Ratio 1 – 5000
Demand Period 1-60 min. adjustable
Connection Type 3F4T, 3F3T
Measurements in Quadrants 4
Number of Measurements in a Period 256
LCD/Display Refresh Period 1 sec.
Networks TT, TN, IT
Min./Max./Demand Values
Energy Measurement Number of Tariffs 1
1Ø Phase Energy Meters
3Ø Phase Energy Meters
Current Measurement Input Measurement Range 10mA – 6A AC
Overvoltage Category 300 V Cat II
Measurement Surge Voltage 2 kV
Power Consumption <0.2 VA
Intermittent Overload 100 A for 1 sec.
Sampling Frequency between 45-65 Hz 12.8 kHz
Voltage Measurement Input Overvoltage Category 300 V Cat III
Measured Range L-N 1-300 Vrms
Measured Range L-L 2-500 Vrms
Measured Frequency Range 45-65 Hz
Power Consumption <0.1 VA
Sampling Frequency between 45-65 Hz 12.8 kHz
Power Quality Measurements Harmonics for Current and Voltage Phases Up to 31st
THD – Voltage in %
THD – Current in %
Other Measurements Run Hour (Operating Time for Load in Hours)
On Hour (Operating Time for Meter in Hours)
Int Counter (Number of Power Interruptions)
Measurement Accuracy According to IEC 61557-12 Total Active Power Class 0.5
Total Reactive Power Class 1
Total Apparent Power Class 0.5
Total Active Energy Class 0.5
Total Reactive Energy Class 2
Frequency Class 0.1
Current Class 0.5
Neutral Current Class 0.5
Voltage Class 0.2
Power Factor Class 0.5
THDV, THDI Class 1
According to IEC 62053-22 Total Active Energy Class 0.5S
According to IEC 62053-23 Total Reactive Energy Class 2
Inputs and Outputs Alarm Relay Outputs Type
Max. Switching Current 10A
Supply Voltage AC 85-300V
DC 85-300V
Consumption AC <6VA
DC <3W
Supply Frequency 45-65Hz
Data Logging with timestamp Min./Max./Avg. Values Hourly Records
Daily Records
Monthly Records
Data Logging with timestamp Demand
Mechanical Properties Weight (g) 272 g
Protection Class Front IP40 / Rear IP20
Mounting Type Panel Mount
Cable Cross Sections Supply, Voltage, Current, Relay Outputs Stranded: 2.5mm² – 14AWG
Solid: 4mm² – 12AWG, 2×1.5mm² – 2x16AWG
Ambient Conditions Operating Temperature -20°C +70°C
Storing Temperature -30°C +80°C
Relative Humidity (No Condensation) Max. 95%
EMC-EMI 300 VAC CAT II according to IEC 61010-1
EN 55011/A1:2010, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-8, EN61000-4-11
Schematics Network Connections
Digital I/O and Alarm Output Connections
3 wires with 3CTs
4 wires with 3CTs
3 wires with 2CTsNOTE: CTs can be connected any phase. They are connected to phase 1 and phase 3 in this figure.
Single Phase with 1CTNORE: CT and VT can be connected any phase. They are connected to phase 1 in this figure.
Digital Output Connection
Digital Input Connection
Alarm Output Connection
Analog Output Connection
Menu